| NEWS
ETCH 557 FGS 20093--- Fountain Solution Concentrate |
| Description: |
|
NEWS ETCH 557 FGS is a low VOC neutral fountain solution developed
for quality four color process printing on high speed newspaper
presses. NEWS ETCH 557 FGR is a particularly well suited for daily
newspaper, inserts, publications and commercial forms. NEWS ETCH
557 FGS contains no petroleum distillates, no EPA priority pollutants,
no chromates or heavy metals and SARA Title Ⅲ section 313 listed
components.
|
| Features: |
- Fast
starts minimize waste
-
Wide range - works well with all new inks
- Less
piling
- Better
desensitizing
- Contains
no gums
- Corrosion
inhibitors increased
|
|
| Directions
|
|
It is recommended that
the starting concentration for NEWS ETCH 557 FGS be adjusted to read
a conductivity of 1000-1200 mmhos over the tap water used. In most
cases, this will be about 2 ounces per gallon. It may be necessary
to make an upward or downward adjustment in order to achieve optimumperformance. |
| |
| NEWSETCH
505CM 20092_Fountain Solution |
| Description: |
|
NEWS ETCH 505 CM is a low VOC neutral fountain solution developed
for quality four color processing printing on high speed newspaper
presses. NEWS ETCH 505 CM is particularly well suited for daily newspapers,
inserts, publications and commercial forms. NEWS ETCH 505 TW contains
no petroleum distillates, no EPA priority pollutants, no hromates
or heavy metals. It will provide extremely fast, clean and sharp start
ups on all conventional dampening systems on cold set commercial presses.
It performs well on spray, brush and turbo dampening systems.
|
| Features |
- Fast
starts minimize waste.
-
Stronger formula, runs at reduced dosage!
-
Wide range - works well with all new inks.
-
Less piling.
-
Better desensitizing.
-
Contains no gums.
-
Contains corrosion inhibitors.
|
| Directions: |
It is recommended that the starting concentration for NEWS ETCH 505
TW be adjusted to read
conductivity of 1000 - 1200 mmhos over the tap water used. In most
cases, this will be about 1.5 to 2 ounces per gallon. It may be necessary
to make an upward or downward adjustment in order to achieve optimum
performance. |
| |
| NEWS
ETCH 600 |
| Description |
NEWS ETCH 600 offers the Ultimate in newspaper fountain solution chemistry,
including faster restarts on CTP plates! It isdesigned to have a very
large operating window by virtue of the large wetting system and superior
surface tension reduction that allows a minimum of water to be used
on press. The non-piling and non-linting components are unique to
cold-web applications, and will provide significant reduction in blanket
wash cycles as well as maintaining superior print quality for extended
run lengths.
NEWS ETCH 600 also contains Anchor’s most effective newspaper biocide
system. This new combination system provides excellent protection
against bacteria and fungus growth in all types of dampening systems;
conventional, brush or spray. |
| Features |
-
Fast starts on CTP plates minimize waste.
- Mild
acid pH runs and restarts cleaner.
- Excellent
bacteria protection.
- Maintains
minimum water levels.
- Fights
calcium deposits in hard water areas.
- Zero
VOC.
|
| Directions |
|
Suggested concentration is 2.0 ounces per gallon (1.5%). This is
the minimum level to ensure best product performance. Add the suggested
range of concentrate to a clean gallon of water at press side to
get the conductivity range that can be used for monitoring. This
range should be 1200-1600 mmhos above the base water.
|
| |
| EMERALD
JRP 2968---Acid Fountain Solution |
| Description |
|
EMERALD JRP is a complete fountain solution specially formulated to
run on aqueous plates. The buffer system is matched for use in medium
to hard waters. EMERALD JRP has a strong buffer system to give clean
press starts and resist contamination. |
| Features
|
- Excellent
buffer system performance for stable pH
- Contains
ink drying stimulators
- Fast
re-starts on all CTP plates
- Prevents
plate blinding
- Works
well on conventional dampening presses, or with alcohol or replacement
-
Strong desensitizing system
|
|
| Directions |
|
EMERALD JRP fountain solution is designed to run at 1.5 to 2.5 percent.
The pH of the working solution will be between 4.1and 4.5 depending
on the alkalinity of the local water. The conductivity should read
approximately 720μS for each percent used over the conductivity of
the water used.Adjust the dosage of EMERALD® JRP and alcohol
or substitute to obtain optimum press performance and record the pH
and conductivity as targets for your quality control checks. |
| EMERALD
SOFT-1 20153 Acid Fountain Solution |
| Description: |
|
EMERALD SOFT I fountain
solution is a complete fountain solution specially formulated
to run on aqueous plates. It becomes an effective two-part alcohol
elimination system when used in conjunction with an alcohol
replacement product. |
| Features: |
- Excellent
buffer performance for stable pH.
-
Contains the finest gum arabic.
-
Fast restarts on all CTP plates.
-
Contains no added phosphate.
-
Eliminates plate blinding.
-
Efficiently eliminates alcohol when used as a two-part system.
-
Strong desensitizing system.
-
Reduces calcium build up on press.
|
| Directions: |
|
EMERALD SOFT
I fountain solution is designed to run at 1 to 3 percent. The
pH of the working solution will be between 3.8 and 4.3 depending
on the alkalinity of the local water. The conductivity should
read approximately 730 mmhos per percent added over the conductivity
of the water used. Adjust the dosage of EMERALD SOFT I and alcohol
substitute to obtain optimum press performance. |
| |
| EMERALD
PREMIUM PPF 20227 One-step Acid Fountain Solution |
| Description: |
|
EMERALD PREMIUM PPF is a one-step, acid fountain solution
product for use in soft to medium-hard water. This product is
designed for use on continuous dampening systems without alcohol
on both sheetfed and web presses. Compatible with all types
of plates, papers, and inks; this product contains extra phosphates
for fast starts and restarts. |
| Features: |
- Will
keep the most difficult reverses open.
-
Non-photochemically reactive and non-HAPs.
-
Efficiently eliminates alcohol.
-
Prevents ink feedback onto form and slip rollers.
-
Only requires a single-stage blender.
-
Wide ink water balance.
|
| Directions: |
|
EMERALD? PREMIUM PPF acid fountain solution is designed to
run at 4 to 6 ounces per gallon.After establishing the working
concentration, the conductivity and pH should be recorded.
This datacan then serve as an on-press quality control tool.The
conductivity per ounce over the conductivity of the water
used will read approximately 265mmhos per oz.
|
| |
| EMERALD
PREMIUM EH 2744--- Acid Fountain Solution |
| Description: |
|
EMERALD PREMIUM EH fountain solution is a one-step alcohol replacement
that runs a medium buffered pH. This pH runs cleaner with less
contamination on alkaline paper. EMERALD® PREMIUM
EH will run clean and restart fast when using any modern positive
or CTP plate. The strong buffer system matches RO to medium
hard water and maintains a stable pH. |
| Features |
- Higher
pH prevents corrosion and resists pH drifts
- Faster
re-starts minimize paper waste
- Safe
for CTP and positive plates
- Replaces
alcohol at 4 percent on web presses
- Economical
at 3.5-4%
- Retards
ink Feedback into the dampening system
- Suitable
for both web and sheet-fed presses
- Strong
buffer system matches most water
|
|
| Directions
|
|
EMERALD PREMIUM EH fountain solution is a one-step formula designed
to run at 3.5-4%. The pH of the working solution will be between
4.5and 5.0, depending upon the alkalinity of the local water
supply. The conductivity should read approximately 380μS per
percent over the conductivity of the water used. The conductivity
and pH of the working solution should be verified to ensure
that the blender is working properly. |
| |
| PRIME
TIME FM-C ETCH 20225 |
| Description: |
|
PRIME TIME FM-C ETCH is a mild acid, cold set web product especially
designed for stochastically imaged plates. The non-pilling and
non-linting ingredients provide a significant reduction in blanket
wash cycles while maintaining superior print quality for extended
run lengths. PRIME TIME FM-C ETCH contains our most effective
biocide system. This combination system provides excellent protection
against bacterial, algae and fungus growth in all types of dampening
systems brush, spray and conventional. A new anticorrosion system
package is also standard for this product. This system is designed
with the most demanding requirements in mind. |
| Features: |
- Reduced
reverse pilling on stochastically imaged plates.
-
Non-linting additive for difficult papers.
-
Excellent bio-growth protection.
-
Maintains consistent print quality during long runs.
-
Corrosion protection.
|
| Directions: |
|
The suggested concentration is 2.0 to 3.0 ounces per gallon
(1.5 to 2.3%).This is the optimum level to ensure best product
performance. Add the suggested range of concentrate to a clean
gallon of water at press side to get the conductivity range
that can be used for monitoring. This range should be 1000 to
1700 mmhos above the base water. |
| |
| EMERALD
PREMIUM QRKW 20180 Acid Fountain Solution
|
| Description: |
EMERALD PREMIUM QRKW fountain solution was formulated
to provide fast, clean restarts on thermal CTP plates. The strong
buffer system helps prevent staining and toning on these plates
and can be used in all but the hardest water. |
| Features: |
- Excellent
buffer performance for stable pH.
-
Proven to provide clean restarts for both thermal CTP and
conventional plates.
-
Recently shown to be an excellent performer on M-3000 presses.
-
Contains phosphate for faster restarts on and complies with
the TEC limit.
|
| Directions: |
EMERALD PREMIUM QRKW fountain solution is designed to
run at 4.5 to 6.0 ounces per gallon on continuous dampening
and 4.0 to 5.0 ounces on brush systems. Conductivity should
read about 450 mmhos above the water. To verify the pH and conductivity
of the press-ready solution, prepare a control sample using
local water at the desired dosage. Record the pH and conductivity
to serve as your target numbers on press. Adjust the dosage
to obtain optimum press
performance. |
|
|
|